Reinforcement of the existing structure to meet increased demand with the addition of conveyors and process utilities. The existing facility consists of prefabricated steel frames and portal frames that have been analyzed for additional equipment loads and reinforced to support these loads. In several instances, reinforcing has been designed to reconfigure the geometry of the existing portal frames to allow for new elements to be installed.